TestIT:Programming InternalDevice

From Nolek Wiki
Jump to navigation Jump to search

5.3.9 InternalDevice

LogStart

Description:
It will start the selected log device.

Code example:

InternalDevice.LogStart(LogDevice,_ResultText,_FileName)
Parameters
Parameter Type Description
Instrument name String or String symbol The instrument name
Result String symbol Symbol to receive result from Log. 'OK' if device starts
FileName String symbol Symbol to the file name of the logged file

LogStop

Description:
It will stop the selected log device.

Code example:

InternalDevice.LogStop(LogDevice,_ResultText)
Parameters
Parameter Type Description
Instrument name String or String symbol The instrument name
Result String symbol Symbol to receive result from Log. 'OK' if device stops

RampStart

Description:
It will start the selected ramp device.

Code example:

InternalDevice.RampStart(TestRamp,_ST01)
Parameters
Parameter Type Description
Instrument name String or String symbol The instrument name
Result String symbol Symbol to receive result from Ramp. 'OK' if device starts

RampStop

Description:
It will stop the selected ramp device.

Code example:

InternalDevice.RampStop(TestRamp,_ST01)
Parameters
Parameter Type Description
Instrument name String or String symbol The instrument name
Result String symbol Symbol to receive result from Ramp. 'OK' if device stops

DLL

Description:
It will execute the selected DLL method in the selected device.

Code example:

InternalDevice.DLL_Execute(_DLLDevice,_CommandName,_TimeoutActive, _Result)
Parameters
Parameter Type Description
Device name String or String symbol The instrument name
Command name String or String symbol The saved Command, representing a DLL method
Timeout active Bool symbol Symbol to display if a timeout occurred
Result String symbol Symbol to hold result (OK or ErrorMsg)


Back to Programming - Commands