TestIT:Guide Step Configuration

From Nolek Wiki
Jump to navigation Jump to search

9.5.2 Step configuration

9.5.2.1 Step

Configuration name Description
Step number The ID number of the step. Must be unique within the guide
Step type Select a step type
Image Select between the images in the assigned image folder

9.5.2.2 Next step

Configuration name Description
OK Enter the step number of the next step if the OK action is run
OK button text The text on the OK button. If no text, the button is hidden
OK I/O Select a symbol to use in the OK action
OK I/O value Select a symbol, wich value will be used in the validation of the OK action
OK Validation type Select the OK validation type
NOK Enter the step number of the next step if the NOK action is run
NOK button text The text on the NOK button. If no text, the button is hidden
NOK I/O Select a symbol to use in the NOK action
NOK I/O value Select a symbol, wich value will be used in the validation of the NOK action
NOK Validation type Select the NOK validation type

9.5.2.3 Go back

Configuration name Description
Can go back Select if the step will be able to go back to a specified step
Go back step Step to go back to
Back button text Text on the back button. If no text, the button is hidden
Go Back I/O Select a symbol to use in the Go Back action
Go Back I/O value Select a symbol, wich value will be used in the validation of the Go Back action
Go Back Validation type Select the Go Back validation type

9.5.2.4 Init validation

Configuration name Description
Use init validation Select if the step should be validated before it is called. See guide step flow
Init Validation value A The value that will be validated
Init Validation value B The value to validate against
Init Validation type Select the Init validation type
Init Validate NOK next step Step to go to if step is not valid

9.5.2.5 Release validation

Configuration name Description
Use release validation Should the release of the next button be validated. See guide step flow
Release Validation value A The value that will be validated
Release Validation value B The value to validate against
Release Validation type Select the Release validation type
Release Validation Success message Enter a message to show when the validation is OK (Optional)
Release Validation not succeeded message Enter a message to show when the validation is NOK (Optional)
Next release I/O OK Select a symbol to be set when the validation is OK
Next release I/O NOK Select a symbol to be set when the validation is NOK
Go to next on valid If yes, the step will continue to the OK step, when the validation is OK

9.5.2.6 Next validation

Configuration name Description
Use next validation Should the next button be validated. See guide step flow
Next Validation value A The value that will be validated
Next Validation value B The value to validate against
Next Validation type Select the Next validation type
Next validation NOK next step The step to go to next if the validation is NOK
Next validation timeout The maximum amount of seconds to wait for the validation
Next Timeout NOK step The step to go to if the next validation times out
Next Validation NOK message Enter a message to display if the validation times out

9.5.2.7 Scan

Only applies if the step is a Scan step

Configuration name Description
Scanned value Select a String symbol to store the scanned value into
Go to next on scan If yes, the step will go to the next step, after a scan

9.5.2.8 Timer

Configuration name Description
Use timer If yes, use a timer on the guide step. Will display a time bar in the top of the step
Timer in seconds Enter the time in seconds
Timeout step Enter a step to go to, if the timer times out


Back to Guide