TestIT:Guide
Contents
9. Guide
The guide service allows you to see the guide in setup. In the first section, a guide workflow is shown.
An overview of the guide:
Options:
9.1 Guide workflow
The figure below shows the general guide workflow.
Explanation of the steps:
Steps | |
---|---|
START | Starting a guide can be done in two ways; - Internal - External |
GUIDE STEP | There are different types of guide steps |
OK | The OK step can be any step in the guide. The action can be: - OK button pressed - OK I/O set |
NOK | The NOK step can be any step in the guide. The action can be: - NOK button pressed - NOK I/O set - Next validation fails |
BACK | The back step can be any step in the guide. The action will be a Back button pressed. |
GUIDE STEP (last) | The OK of the last guide step, depends on which guide is running. - Internal is going to close after the last step. Set the OK step to a guide number, NOT in the guide. - External is going to start over after the last step. Set the OK step to the appropriate guide step. - External is going to close after the last step. Set the OK step to a guide which tells the user to close the guide. |
9.1.1 Guide step flow
The figure shows an overview of a guide step flow, like where the validation of the workflow is: TestIT:9guide:930.png?direct&300
__Explanation of the flow:__ | INIT VALIDATION | Before opening the guide step, the init validation is running. \\ - If the validation is OK, the guide step will open \\ - If the validation is not ok, the init validation NOK step will be opened | | GUIDE STEP | The actual guide step is opened | | RELEASE VALIDATION | The release validation is running while the step is open. \\ - If the validation is OK, the OK button will be released \\ - If a next release I/O is selected, it will be set on validation OK \\ - If a validation success message is set, this will be shown on validation OK | | NEXT VALIDATION | If OK button is pressed or OK I/O set, the next validation will be running \\ - If a timer is set, it will start \\ \\ - If the validation is OK, the next guide step will open \\ - If not, the validation will keep running for the timeout period \\ \\ - If the timeout runs out, the timeout message will be shown or the timeout step will be opened |