TestIT:Programming Serial
Revision as of 15:03, 14 August 2019 by NolekAdmin (talk | contribs) (Created page with "==5.3.11 Serial== ===RS232=== '''Description:''' <br /> It will execute serial device. '''Code example:''' :<code>Serial.RS232(Port1,_ST01,_ST02,10,S,TimeoutActive)</code> {...")
5.3.11 Serial
RS232
Description:
It will execute serial device.
Code example:
Serial.RS232(Port1,_ST01,_ST02,10,S,TimeoutActive)
Parameters | ||
---|---|---|
Parameter | Type | Description |
Device name | String or String symbol | The device name |
Send | String or String symbol | Text to send |
Received | String or String symbol | Text received from COM port |
Timeout | Int or Int symbol | Time before the communication times out |
Time unit | String | Select the time unit, from the list |
Timeout active | Bool symbol | True if timeout active |
RS232ADV
Description:
It will execute serial advanced device.
Code example:
Serial.RS232ADV(Serial,1,"!R",_ST01,10,S,TimeoutActive,_IN01,S,_B01,AlwOFF)
Parameters | ||
---|---|---|
Parameter | Type | Description |
Device name | String or String symbol | The device name |
CriteriaType | Int | Select if any criteria. 0: None, 1: Begins with, 2: Contains |
Criteria | String or String symbol | The value to test against |
Received | String or String symbol | Text received from COM port |
Timeout | Int or Int symbol | Time before the communication times out |
Time unit | String | Select the time unit, from the list |
Timeout active | Bool symbol | True if timeout active |
Time active | Int or Int symbol | Time before receiving |
Time unit | String | Select the time unit, from the list |
Active | Bool symbol | Symbol to hold active value |
Keep alive | Bool symbol | Keep connection open |