98. Appendix

98.1 Response values

98.2 Log ID values

98.3 Extra

98.3.1 Stored procedures

When uploading results using an OPC READ controller, without using a Nolek stored procedure: The procedure must expect ComputerName, GroupName, ClientDateTime, Checksum, Temp02 as the first parameters, before the tags to upload. The ClientDateTime is a date and the rest are texts.

98.3.2 ClientDateTime value

When the time setting of the computer is changed while the DataConnectIT service is running (e.g. changing to daylight saving time) the ClientDateTime value of any uploaded results will not take this change into account until the service is restarted.

98.3.3 Permissions

To start and stop the DataConnectIT service from within the program, DataConnectIT must be installed as an administrator (Setup.exe). Otherwise, the Windows service area will be greyed out.