TestIT:Appendix
Revision as of 10:35, 20 August 2019 by NolekAdmin (talk | contribs)
Contents
12. Appendix
12.1 Change log
Vers. 1.2.5
Vers. 1.2.5
Database
- DB UPDATE 1.2.5
S9 Device
- Added mosCura recipes/S9 recipes
GUIDE
- Run Leak device from guide
- Store procedure step added
- Updated list and card view with info and icons.
INFO
- Added Setup and Prod db info
Command
- Bug on AddResultValidate fixed (bool)
- New: StringDecToChar
- New: FileExecute
Device
- Added: FileDevice. .bat + .exe / Execute incl. test area
- Log device, + Command: LogStart, LogStop
Vers. 1.2.4
Vers. 1.2.4
MSSQL
- Autofill on parameters in test area
- Count on parameters in output
- Float to double symbols.
Tile screen
- Less padding to fit screens better.
Vers. 1.2.3
Vers. 1.2.3
Database
- DB UPDATE 1.2
Bug
- System_Stop sequence cleared
Symbols
- Start, Stop, EMG sleep from 250 ms to 50 ms to optimize the process.
- Wait sleep from 100 ms to 50 ms to optimize process
- Input and Output symbol scaling in decimals
12.2 Requirements
PC and software
- Windows 7 (x86 or x64)
- .Net framework 4.5
- Processor running at 1,6 Ghz or higher
- 4 GB RAM
- Graphics adapter supporting DirectX9, running at a minimum resolution of 1024x768
- Processor: Intel (R)
Note!
- We recommend that the desktop/PC is installed with two TCP/IP card; one for the TwinCAT communication and one for communication with the administrations network.
SQL 2008 Express version
- SQLEXPRWT_x64_ENU
- SQLEXPRWT_x86_ENU
Version 10.50.1600.1
TwinCAT version
- TC31-Full-Setup.3.1.4018.16